1
|
Sector
|
Labour And Manpower Tenders
|
Tender Value
|
N.A.
|
Location
|
Bihar Tenders
|
Ref.No
|
71167289
|
Closing Date
|
02 - May - 2024
|
12 Days to go
|
View Tender Details
|
|
Supply of Current Transformer, Potential Transformer, Capacitors, Various Electronic components, High pressure sodium Lamp, Bus bar with brackets, LT fuse set Henley Unit, 11 KV DO fuse set, Fuse Wire, LT Shackle Insulator, Bucholtz relay, Breather with Silica Gel And Oil, ACSR Conductor, HT XLPE Cable, LT PVC insulated cable, Twisted pair cable other cable, Aerial Bunched Cable ABC, 11KV pin insulator, 11 KV pin with nut, 11 KV disk insulator, 11 KV suspension fitting, 33 KV tension fitting, Cross arm, Universal Motor with starter switch - TITLE1 Qty : 151
|
|
|
2
|
Sector
|
Power Plant Tenders
|
Tender Value
|
N.A.
|
Location
|
Bihar Tenders
|
Ref.No
|
70865095
|
Closing Date
|
30 - Apr - 2024
|
10 Days to go
|
View Tender Details
|
|
Procurement of Spares for Chloride Make 220 V, 400 a Dc Battery Charger Dcps Card for Dig.meter: Dcps01;chloride, Ac Voltmeter:cl:0.5:48x48/48x96:0-500v, Ammeter:dc:cl:0.5:48x48/48x96:0-150a, Dc Voltmeter:0-400v,cl:0.5,size:48x48mm2, Ammeter:ac:cl:0.5:48x48/48x96:0-75a, Sec.line Surge Suppressor; Caldyne, Snubber Network Card: 0.22mf/1000v;caldn, Diode:blocking Diode:800v, 300a, Bc:caldyne:220v-100a:thyristor, Rectifier Fuse Fail Indicator; Caldyne, Bleeder Resistance 1k/50w, Potentiometer Wirewound-10k Ohm/3 Watt, Filter Capacitor, Electronic Scr Controller Pcb; Caldyne, Dc Under Voltage Monitor Card:, Gflc Card - Static, Card No-135; Caldyne, Ac Supply Fail relay Modul: Acstr,415vac, Float/boost Selector Switch, Annunciation relay Module: Ann01;chlorid, Current Limit relay Card: Clr01;chloride, Heatsink Block, Scr Control Module: Avr/acr01; Chloride, Aux.relay: 110/125v Dc,pla,3 C/o Contact, Bc:caldyne:220v-100a:ip Protection relay, Offload Changeover S/w 4p, 6a,440v Ac,
|
|
|
3
|
Sector
|
Power Plant Tenders
|
Tender Value
|
N.A.
|
Location
|
Bihar Tenders
|
Ref.No
|
66320816
|
Closing Date
|
29 - Apr - 2024
|
9 Days to go
|
View Tender Details
|
|
Supply of 400kV Eastern Bus Bar Scheme, Duplicate Numerical Low Impedance Centralized Busbar Protection relay, 400kV Eastern Bus Bar Scheme, Panels for fixing centralized Busbar units, Trip relays, Supervision relays etc, 400kV Eastern Bus Bar Scheme, Spare Bus Bar relay, 400kV Eastern Bus Bar Scheme, One spare Auxiliary relay of each type used in retrofitment work, 400kV Eastern Bus Bar Scheme, Retrofit accessories like interpanel wiring, Test block, etc as per requirement, 400kV Eastern Bus Bar Scheme, 5C X 2 5 sq mm control cable for CT input, 400kV Eastern Bus Bar Scheme, 10C X 2 5 sq mm control cable for CB status, 400kV Northern Bus Bar Scheme, Duplicate Numerical Low Impedance Centralized Busbar Protection relay, 400kV Northern Bus Bar Scheme Panels for fixing centralized Busbar units, Trip relays, Supervision relays etc, 400kV Northern Bus Bar Scheme Retrofit accessories like interpanel wiring, Test block, etc as per requirement, 220 kV Bus Bar Scheme, Numerical Low Impedance Centralized Busbar Protection scheme for, 220 kV Bus Bar Scheme, Panels for fixing centralized Busbar units, Trip relays, Supervision relays etc, 220 kV Bus Bar Scheme, One spare Auxiliary relay of each type used in retrofitment work, 220 kV Bus Bar Scheme, Retrofit accessories like interpanel wiring, Test block, Test plugs, cable lugs etc as per requirement, 220 kV Bus Bar Scheme, 10C X 2 5 sq mm control cable for Isolator status, 132 kV Bus Bar Scheme, Numerical Low Impedance Centralized Busbar Protection scheme, 132 kV Bus Bar Scheme, Panels for fixing centralized Busbar units, Trip relays, Supervision relays etc, 132 kV Bus Bar Scheme, One spare Auxiliary relay of each type used in retrofitment work, 132 kV Bus Bar Scheme, Retrofit accessories like interpanel wiring, Test block, Test plugs, cable lugs etc as per requirement, 220 kV Bus Bar Scheme, Numerical Low Impedance Centralized Busbar Protection scheme, 220 kV Bus Bar Scheme, Spare Bus Bar relay, 220 kV Bus Bar Scheme, Retrofit accessories like interpanel wiring, Test block, etc as per requirement, 400 kV Bus Bar Scheme, LBB relays, IEC61850 compliant, 400 kV Bus Bar Scheme, Spare LBB relay, Retrofitting Erection, testing Commissioning, 400kV Eastern Bus Bar Scheme, Retrofitting Erection, testing Commissioning, 400kV Northern Bus Bar Scheme, Retrofitting Erection, testing Commissioning, 220 kV Bus Bar Scheme, Retrofitting Erection, testing Commissioning, 132 kV Bus Bar Scheme, Retrofitting Erection, testing Commissioning, 220 kV Bus Bar Scheme, Retrofitting Erection, testing Commissioning, 400 kV LBB Scheme - supply retrofitting of Busbar AND Protection relays Qty : 9051
|
|
|
|
5
|
Sector
|
Power Plant Tenders
|
Tender Value
|
N.A.
|
Location
|
Bihar Tenders
|
Ref.No
|
71005085
|
Closing Date
|
26 - Apr - 2024
|
6 Days to go
|
View Tender Details
|
|
Procurement of Lt Switchgear Spares for Brbcl Nabinagar Xfmr,curr,200/1a,15va,cl-1/5p20, Xfmr,curr,150/1a,0.415/0.66kv,7.5va,cl-1, Xfmr,curr,metering,wpl,resin Cast,100/1a, Xfmr,curr,75/1a,7.5va,cl-1, L&t:fn315/400/630/800 Hndl Asy-b:sk91279, Mcc:l&t:fn-200/250 Handle Assy.-b, Mcc:l&t:fn-32/63 Handle Assy.- Ce, L&t:handle Assy-a for Fn125:sk912580000, Xfmr,pot,415/110v,50va,cl-1, Xfmr,pot,415vr3/110vr3,50va,cl-1, Xfmr,curr,ring,resin Cast,3000/1a,cl-ps, Xfmr,curr,3000/1a,0.415/0.66kv,7.5va, Xfmr,curr,resin Cast,1000/1a,cl-ps, Xfmr,curr,1000/1a,0.415/0.66kv,7.5va, Xfmr,curr,630/1a,0.415/0.66kv,7.5va, Power Contctr.: 3p, 110vac, L&t-mnx18, Pwr.contctr.: 3p,110vac,110vac,l&t-mnx32, Powr Contr:3p415vac:110vac:l&t:mnx70, Power Contctr.: 3p,110vac, L&t-mnx110, Power Contactor Mnx225, 415 Volts, Ac3,, Contactor,power,415vac,400a,3p,l&t, Coil,cs94142,l&t,contactor,mnx265, Contact Block 1no+1nc,2nd Left-#cs94207, Contact Block 1no+1nc-second Right-cs942, Side Add on Lhs,1no+1nc for Mnx9-40,cs94, Side Add on Rhs,1no+1nc for Mnx9-40,cs94, Switch Disconnector Fuse Tpn Fn125 L&t, Switch Disconnector Fuse Tpn,fn250 L&t, Switch Disconnector Fuse Tpn Fn400 L&t, S/w Rotry Waf:4 Way:440v Ac, 32a:salzer, Rotry Waf S/w On/off 240vac 25a Salzer, O/l Mn12l 66-110a,l&t Make, Selectr.switch: 4-posn,16a,220vdc;salzer, S/w Sel:on / Off:16a 220vdc:salzer, S/w Sel:2:pos:16a,240vac:salzer, S/w Rotry Waf:4 Way:660v Dc,25a:salzer, Racking Nut for L&t Module, O/l relay Type Mn2 L&t 0.9-1.5 a, relay,thermal O/l,0.6-1a,mn2,l&t, Thermal Bi-metal O/l relay:mn2,0.3-0.5a, Bimetal O/l relay Type Mn2 Range4.5-7.5a, Thermal Overload relay:a1.4-2.8, 6-10amp Over Load relay L&t Make, Rely Th O/l:14-25 A:l&t Make Mn2, O/l relay L&t Mn2; 9-15a Singleeph.prot., Overload relay Range : 3-5a, Type:mn2, Thermalo/lrlymn12,135a -225a,ss94138,l&t, Ct Opr Bim;90-150a;mn12;l&t-ss94138oomo, Pulling Handle,sk 91185,l&t, Right Micro Switch for L&t Make Acb, Left Micro Switch for L&t Acb, Microswitch Test/isolate Position Right, Microswitch Test/isolate Position Left, Charging Motor,sl00347oooo,l&t, Closing Coil 220v Dc for L&t Make Bkr., Shunt Release Ea 220v Dc 501-30-98266, Frcd for L&t Make Cn-cs 4000a Edo, Resistor Kit (220 V D.c.)for L&t Acb, Racking Interlock for L&t Breaker, Bezel for C-pwr.brkr-1250a, #sl916020000, Elect Position Indication for L&t Acb, Panel Door Ingress Seal, D/out Acb, Stablsng Resstr Varabl 0-2000ohm200w 1a, Lock a Type for L&t Acb Rackout Locking, Cam Lock for Doors of L&t Switch Gear, Door Interlock for L&t Make Acb, Lt Air Circut Breaker Key Lock T-aklaf12, Reset Cord for Over Load relay, Lt Swtch Gr:reset Cord 1metre Long, Kit Mount Mn2 relay Onn Ml0/1/1.5, 6 Way Sic Block Cat No. Sl92701; L&t, Sec Isoltng Cont(s+t)brak-f/m L&t Make, Sec Isoltng Cont(s+t)serv-f/m L&t Make, Sec Iso Cont Serv Sa92567 for Lt S/g, L&t-sec Iso Contact Male - Sa92565, Racking Handle of L&t Modules, Racking Handle for L&t Acb, Aux Cont Kit Typ Fn315 C No.sk91330 L&t, Aux Cont Kit Typ Fn200/250 C No.sk91329, Aux Cont Kit Fn100/125/160c No.sk91328, Auxiliary Contact Kit for Fn63, Aux Contr:l&t:add on Block-cs94112, Aux Contr: L&t-add on Block, Cat-cs94113, Aux Contr: L&t-add on Block-cs94114, Aux Contr: L&t-add on Block-cs94120,f, Aux Contactor: L&t-add on Block-cs94121, Contactor,auxiliary,110vdc,6a,2no+2nc, Frcd,for,1250 /2500/4000a, Acb, Spare Kit L&t Make for Mnx110 Contactor, Spare Kit Without Coil Mnx225 Cat-94157, Spare Kit Without Coil Mnx400 Cat-94161, Powr Contr:2p 22vdc:cv 220vdc:200a, Spring Charging Assy,sl90686oooo,l&t, Front Facia- for Electrical Acb,sl93202, 220 V Dc Spring Charge L/switch Assy,l&t,
|
|
|
|
|
8
|
Sector
|
Telecommunication Services / Equipments Tenders
|
Tender Value
|
1.57 Million approx. / 15.76 Lakh approx.
|
Location
|
Bihar Tenders
|
Ref.No
|
71149642
|
Closing Date
|
22 - Apr - 2024
|
2 Days to go
|
View Tender Details
|
|
Supply of Attending Fault, Capcitor, relay, Selector, Fan Motor, Capallary, Board, Cable, Copper, Shaft, Fan Blade, Mcb, Runner, Refrigerent, Rewinding, Rotaory Comp, Reciprocating Comp, Replacement Comp - Repairing of Sac Units Qty : 1335
|
|
|
|
|